Search Results "Recessed Lavatory"
Commonly Searched Documents
- American Specialties Recessed High Speed Hand Model 20199
-
Bobrick TrimLineSeries Recessed Sanitary Napkins Disposal B-35303
Requires the Premium User plan or above. (Login or upgrade your account!)
-
H11
If mirrors are provided, is the bottom of the reflecting surface for the mirror at this lavatory no higher than 40 inches above the floor or is a full length mirror provided?...
-
Forward and Side Approaches
A forward approach is required at some elements, such as drinking fountains and lavatories, for easier access....
-
213.3.1 Toilet Compartments
A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing....
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
604.5.2 Rear Wall
shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location of a recessed...
-
11B-233.3.1.2.6.5 Additional requirements.
Water closet, bathtub and lavatory maneuvering clearances complying with Section 11B-809.10. 10. Removable base cabinets complying with Section 11B-809.9.3....
-
Mirrors [4.19.6]
Mirrors [4.19.6] ADAAG does not require a mirror above the lavatory but requires that if mirrors are provided, at least one must be accessible....
-
§382.63(a)(3)
(3) The lavatory shall provide door locks, accessible call buttons, grab bars, faucets and other controls, and dispensers usable by qualified individuals with a disability, including wheelchair...
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
4.3.9 Doorway Design
the passage task on the pull sides of Doors 1, 800 mm (31.5 in.) latch clearance, and Door 2, 406 mm (16 in.) latch clearance, demonstrate that an 457 mm (18 in.) clearance required in recessed...
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
This would mean that the wing wall could not extend beyond the front edge of a lavatory located on the other side of the wall from the water closet....
-
A. Accessible Toilet Rooms
Is each public and employee restroom accessible, with at least one large accessible stall/toilet, one accessible lavatory, and one accessible urinal (if urinals are provided)?...
- Bobrick Recessed Heavy Duty Specimen Pass-Through Cabinet B-50517
- AJW Architectural Products US80 Security Soap Dish, Chase Mount - Recessed
- Gamco Recessed Mini-Towel Dispenser and Waste Receptacle Combination - TW-3
- Inpro Corporation JointMaster® 441 Series-Recessed Mount Expansion Joint
- Gamco Recessed Coverall Combination Towel Dispenser and Waste Receptacle - TW-9
- Bobrick Recessed Heavy Duty Specimen Pass-Through Cabinet B-50516
- Mockett PCS46/ALM Recessed Aluminum Grommet with 6 Power & 4 Data