M3. Is the hardware (e.g., lever, pull, etc.) usable with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.13.9]    Yes   No If No,...
Search Results "Power Assisted Door"
Commonly Searched Documents
-
M3
-
407.3.3.1 Height
407.3.3.1 Height. The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish...
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically....
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. Â ...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
-
H24
Unless the wide stall is located at the end of a row of toilet stalls, does the door to this wider stall open out? [ADA Standards § 4.17.3]    Yes    No...
-
Introduction
[See subsections ...]
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
Whether the definition of ‘‘wheelchair'' includes the Segway® PT. (Section-by-Section Analysis)
The basic Segway® PT model is a two-wheeled, gyroscopically-stabilized, battery-powered personal transportation device....
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Door Arm Pivot Variations Video
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Adjusting Spring Door Tension Video
- Access Board: Automatic Door Controls
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
5.2 Distributing Receivers
Assist listeners in selecting the appropriate coupling arrangement (headphones, neckloop, earbuds, etc.). Briefly instruct users in how to operate the receiver....
-
4.21.4 Grab Bars
On the one hand, transfers are typically only made into shower chairs outside the shower and with a caregiver’s assistance....
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]