Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
Search Results "Operation (Elevator)"
-
11B-407.4.6.1 Location
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
1007.4 Elevators
An elevator to be considered part of an accessible means of egress shall comply with the emergency operation and signaling device requirements of Section 2.27 of ASME A17.1....
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
Door and Signal Timing
This provision helps ensure that elevator doors remain open long enough for persons with disabilities to travel from call buttons to the responding car and is based on a travel speed of...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
Section 37.169 Interim Requirements for Over-the-Road Bus Service Operated by Private Entities
Section 37.169 Interim Requirements for Over-the-Road Bus Service Operated by Private Entities Private over-the-road bus (OTRB) service is, first of all, subject to all the other private...
- NORTON 5600 Executive Video
-
M307.2 Tactilely Discernible (Section-by-Section Analysis)
The MDE NPRM proposed that operable parts intended for patient use be tactilely discernible without activation....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
A4.31.3 MOUNTING HEIGHT
In localities where the dial-tone first system is in operation, calls can be placed at a coin telephone through the operator without inserting coins....
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum.