Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
Search Results "Multi-User Toilet Room"
Commonly Searched Documents
-
703.5.7 Stroke Thickness
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
§ 36.403(f)(1)
(1) Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of...
-
§ 36.403(f)(2)
(2) Costs that may be counted as expenditures required to provide an accessible path of travel may include:
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms). Letters and numerals shall be raised 1/32 in, upper case, sans serif or simple serif type and shall be...
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous. It also...
-
4.30.4* RAISED CHARACTERS OR SYMBOLS
Letters and numbers on signs shall be raised 1/32 in (0.8 mm) minimum and shall be sans serif characters. Raised characters or symbols shall be at least 5/8 in (16 mm) high, but no...
-
11B-703.4 Installation height and location
11B-703.4 Installation height and location. Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
11B-703.5.7 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
- Georgia-Pacific Compact® Vertical Double Roll Bathroom Tissue Dispenser 56782
- Georgia-Pacific Compact® Translucent White Vertical Double Roll Bathroom Tissue Dispenser 56767
-
3) Signs
3) Signs ADAAG: * Signs designating permanent rooms and spaces (men's and women's rooms; room numbers; exit signs) must have raised and Brailled letters; must comply with finish and...
- Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
-
224.4 Guest Rooms with Communication Features
In transient lodging facilities, guest rooms with communication features complying with 806.3 shall be provided in accordance with Table 224.4....
-
F224.4 Guest Rooms with Communication Features
In transient lodging facilities, guest rooms with communication features complying with 806.3 shall be provided in accordance with Table F224.4....
-
E207.2.1 Word Substitution when Applying WCAG to Non-Web Software
For non-Web software, wherever the term “Web page” or “page” appears in WCAG 2.0 Level A and AA Success Criteria and Conformance Requirements, the term “software” shall be...
-
805 Medical Care and Long-Term Care Facilities
Revisions made to this section include: removing a stipulation that wheelchair turning space not extend beneath beds (805.2) clarifying fixture requirements in accessible toilet...
- Georgia-Pacific Compact® Translucent Smoke Vertical Double Roll Coreless Tissue Dispenser 56790