Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
11B-505.4 Height
-
8.1 Q. The Fair Housing Act applies to covered multifamily dwellings built for first occupancy after March 13, 1991. What is acceptable evidence of first occupancy?
The determination of first occupancy is made on a building by building basis....
- UltraPlay Recycled Rubber Tile Surface
- WoodCarpet Ground Surface System: WoodCarpet Mat Installation Video
-
3.2.4 Slope
The ground surface in all camp living areas shall have a slope of no more than 1:48 (2 percent) in any direction. Exception....
- NanoPave® 2-in-1 Joint Stabilizer and Sealer
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
Wiring for Visible Alarms [§215.3]
Wiring for Visible Alarms [§215.3] All employee work areas served by audible fire alarms, regardless of size, must be designed to support later installation of visible alarms after...
-
203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 203....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
- Inpro Corporation JointMaster® 441 Series-Recessed Mount Expansion Joint
-
(3) Adjustability: Transfer Surface Intermediate Heights
In the MDE NPRM there was no requirement for the transfer surface to have intermediate transfer heights....
-
Compliance Determinations by State and Local Jurisdictions
to attend staff reviews of every building permit request....
-
Visible Alarms
The 1991 Standards, at section 4.1.1(3), require visible alarms to be provided where audible fire alarm systems are provided, but do not require areas used only by employees as work areas...
-
Performance and the Surface Deficiency Score
In an effort to statistically analyze the frequency of identifiable deficiencies between surface types, the Surface Deficiency Score (SDS) was developed. ...
-
High work surface
All of the seating spaces/work surfaces were approximately 42" high....
-
4.1.1(2) Application Based on Building Use
(2) Application Based on Building Use....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
T302 Walking Surfaces
The technical requirements for walking surfaces include provisions on slip resistance, the maximum size of surface openings, and the maximum height of vertical surface discontinuities (i.e...
-
1.9.1.2.1
1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1....
-
1.9.1.2.1
1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1....
-
A4.5.3 Carpet
Much more needs to be done in developing both quantitative and qualitative criteria for carpeting (i.e., problems associated with texture and weave need to be studied). However,...
-
Carpet [§302.2]
Carpet [§302.2] Carpet that is thick, cushiony, or loose impairs accessibility, particularly wheelchair maneuvering. The standards specify the maximum pile height (1/2” measured...
-
14) Carpet and carpet tile
14) Carpet and carpet tile ADAAG: Same standards for carpet and carpet tile: maximum pile height of 1/2" (§4.5.3). UFAS: Carpet must have maximum pile height of 1/2". Carpet...