Exception: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play...
Search Results "Curb Ramp"
-
11B-240.2.1.2 Additional number and types
-
d-iv
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...
-
f-vii
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...
-
4c.
Are the handrails mounted between 34 and 38 inches above the ramp surface? [ADA Stds 4.8.5] Yes _____ No _____...
-
1.2.3 Landings
Both measurements of ramp landings as described in Section 1.1.15 should not exceed a plus tolerance of 0.5%....
-
11B-812.5.3 Relationship to accessible routes
A curb, wheel stop, bollards, or other barrier shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
11B-812.5.3 Relationship to accessible routes
A curb, wheel stop, bollards, or other barrier shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
A4.8.5 Handrails
The requirements for stair and ramp handrails in this guideline are for adults....
-
A4.8.5 HANDRAILS
The requirements for stair and ramp handrails in this standard are for adults....
-
§ 38.73(d)(4) Exception
practicable to meet the horizontal or vertical requirements of paragraphs (d) (1), (2) or (3) of this section, platform or vehicle devices complying with §38.83(b) or platform or vehicle mounted ramps...
-
12. If ramp access is provided to at least 50% of elevated play components and 3 different types of elevated play components can be accessed by a ramp, do any additional ground level accessible play components need to be provided?
If ramp access is provided to at least 50% of elevated play components and 3 different types of elevated play components can be accessed by a ramp, do any additional ground level accessible...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal...
-
Temporary Solutions for Election Day
Suggestion: Install a portable ramp with edge protection and handrails as shown in the figure or relocate the accessible voting to another area that is on an accessible route....
-
Handrails [4.8.5]
Handrails are required on both sides for ramps with a rise more than 6 inches or a horizontal length more than 72 inches....
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope....
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
The vertical clearance at doorways with lifts, ramps or bridgeplates shall comply with T502.2....
-
Doorways at Landings [§405.7.5]
Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
-
Outdoor Conditions [4.8.8]
Exterior ramps must be designed so that water does not accumulate on the ramp or landing surface. A slope up to 2% is allowed at landings for adequate drainage....
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope....
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.