Showers required by Section 11B-809.10 shall comply with this section.
Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
Commonly Searched Documents
-
11B-809.10.6 Showers
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
Sections 1630.2(a)-(f) Commission, Covered Entity, etc.
Sections 1630.2(a)-(f) Commission, Covered Entity, etc....
-
11B-608.6 Shower spray unit and water
care facilities, transient lodging guest rooms, or residential dwelling units....
-
F229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with F229. 2....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
3(2)
(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
A. No. The requirements in the Guidelines must be included at the time of construction. Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that...
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches.
-
7(2)(b)(ii)
(ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is...
-
11B-229.1 General
Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229. 2. ...
-
E101.4 Units of Measurement (Section-by-Section Analysis)
E101.4 Units of Measurement (Section-by-Section Analysis) This section would note measurements are stated in U.S. customary and metric units and that the values stated in each system...
-
C101.4 Units of Measurement (Section-by-Section Analysis)
C101.4 Units of Measurement (Section-by-Section Analysis) This proposed section, which also has a counterpart in the proposed 508 Standards (E101.4), provides that measurements are stated...
-
§8.22 New construction—housing facilities.
[53 FR 20233, June 2, 1988, as amended at 56 FR 920, Jan. 9, 1991]