Automated Doors Maneuvering clearance is required on the egress side of automated doors unless they are equipped with standby power or they stay open in power-off mode (§404.3.2)...
Search Results "Clearance"
Commonly Searched Documents
-
Other Requirements in the ADA Standards
-
404.1 General
404.1 General. Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by...
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel...
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel...
-
Position [§305.5]
Position [§305.5] At most elements, clear floor or ground space can be positioned for either a forward or a side approach. For better usability, a forward approach is required at...
-
Components of Accessible Routes
[See subsections ...]
-
Vertical clearance and protruding objects
• Entrances and aisles with adequate head clearance and minimal projections into the path of travel result in easier navigation for people with lessened visual acuity or those who may be...
-
1003.3.2 Boarding Pier Clearances
1003.3.2 Boarding Pier Clearances....
-
306 Knee and Toe Clearance
Section 306 defines the minimum clearances for knees and toes beneath fixed objects. Few comments addressing this section were received....
-
1003.3.1 Boat Slip Clearance
Advisory 1003.3.1 Boat Slip Clearance Exception 3....
-
Interior Routes
Exposed edges securely fastened with trim on exposed edge. 11B-302.2 Vertical clearances/protrusions along circulation paths. 11B-307...
-
Interior Routes
Exposed edges securely fastened with trim on exposed edge. 11B-302.2 Vertical clearances/protrusions along circulation paths. 11B-307...
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.) (1) 30" minimum countertop space for sink installation with...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
-
4.21.2 Size and Clearances
4.21.2 Size and Clearances....
-
1003.3.2 Boarding Pier Clearances
Advisory 1003.3.2 Boarding Pier Clearances. These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps....
-
4.34.5.5(1) Size and clearances
(1) Size and clearances. Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
1003.3.1 Boat Slip Clearance
Advisory 1003.3.1 Boat Slip Clearance Exception 3....
-
11B-608.2 Size and clearances for shower compartments
11B-608.2 Size and clearances for shower compartments. Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
- Access Board: Multi User Toilet Room Layout