(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
Search Results "Clear"
Commonly Searched Documents
-
9.5.2(2)(a)
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
Forward Approach
The Board has revised the rule to require a clear floor space for a forward approach at all wheelchair accessible drinking fountains (602.2)....
-
604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
4.4.1* GENERAL
Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e)). Figure 8 Protruding Objects...
-
Measuring Door Openings
Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
Lavatories Adjacent to Partitions
Per 11B-606.2, we know that a clear space positioned for a forward approach is required (with exceptions), with proper knee and toe clearance. ...
-
222 and 803 Dressing, Fitting, and Locker Rooms
Some commenters stated that clothing and retail stores would have to expand and reconfigure accessible dressing, fitting and locker rooms to meet the changed provision for clear floor space...
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations shall comply with Sections 11B-309 and 11B-902. Baby diaper changing stations when deployed shall not obstruct the required width of an accessible route...
-
604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
1014.2.1.1.2 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
Vending Machines and Other Equipment [5.8]
Vending Machines and Other Equipment [5.8] Since vending machines often are not fixed, ADAAG only requires that clear space be available at them for a forward or side approach and that...
-
1014.2.1.1.2 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
7(2)(b)(vii)
A minimum clear floor space 2'6" wide by 4'0" should be available outside the stall. (See Figure 7(d).)...
-
(1)(e)
(e) Doorways on the end of the enclosure, opposite the water closet, should have a minimum clear opening width of 32 inches (815 mm)....
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 (2 percent) in any direction....
-
§ 38.23(c)(2) Ramp surface
The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch high; shall have a clear width of 30 inches; and shall accommodate...