A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
Search Results "Building Permit"
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
-
Alterations to prison cells.
The unique environment and security concerns of a correctional facility present challenges that are not an issue in other government buildings, so the Department must strike a balance between...
-
Scoping [4.1.3(5)]
Thus, if a building has two floors and only one provides any occupiable space, there is no requirement for an elevator....
-
Tread Surface: ADA Standard Section 504.4
Section 504.4 covers the current ADA Standards for the tread surfaces on stairways.
- SafePath: ADA Door Access - What is a Level Landing?
- EZCurb Ramp - Vertical Barrier Removal Instructional Video
-
11B-308.4 Suggested reach ranges for children
Where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children, the suggested dimensions of Table 11B-308.4 shall be permitted....
-
410.5 Digital Encoding of Speech
EXCEPTION: Where ICT is a closed system, conformance to standards other than ITU-T Recommendation G.722 shall be permitted where equivalent or better acoustic performance is provided and...
-
11B-308.4 Suggested reach ranges for children
Where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children, the suggested dimensions of Table 11B-308.4 shall be permitted....
-
V. Utilizing the 2010 Standards
HUD is permitting use of the 2010 Standards as an alternative accessibility standard with the following exceptions....
-
11B-206.4.2 Parking structure entrances
Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with Section...
-
11B-206.4.2 Parking structure entrances
Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with Section...
-
11B-405.2 Slope
[2010 ADAS] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are...
-
Exterior/ Fire Doors
Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....
-
11B-405.2 Slope
[2010 ADAS] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are...
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
ACCESSIBILITY
[DSA-AC] Accessibility is the combination of various elements in a building, facility, site, or area, or portion thereof which allows access, circulation and the full use of the building...
-
ACCESSIBILITY
[DSA-AC] Accessibility is the combination of various elements in a building, facility, site, or area, or portion thereof which allows access, circulation and the full use of the building...
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
Entrances from Tunnels or Elevated Walkways: ADA Standard Section 206.4.3
Section 206.4.3 covers scoping requirements in the most current ADA Standards for accessible routes to entrances from tunnels or elevated walkways.
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...