10 [§ 4.7.5] Answer this question only if you skipped the previous two questions because the curb ramp you are surveying does not have flared sides....
Search Results "Boarding Ramp"
Commonly Searched Documents
-
10 [§ 4.7.5]
-
406.8 Detectable Warnings
A curb ramp shall have a detectable warning complying with 705....
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails and Beach Access Routes
Federal agencies shall notify the Access Board if an entire trail is exempted from complying with 1017 based on Exception 2 in 1017.1, and if a beach access route is not provided based on...
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
Islands [§406.7]
Islands [§406.7] A 48” min. long separation is necessary between curb ramps so that people using wheelchairs can clear one ramp before negotiating the next....
-
R304.3.1 Turning Space
A turning space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided at the bottom of the curb ramp and shall be permitted to overlap other turning spaces and clear spaces....
-
Can ramps be portable or provided after construction as an adaptation?
All required ramps and curb ramps must be permanent and installed at the time of construction or alteration with few exceptions....
-
1.1.4
1.1.4 A maximum overall design running slope for exterior accessible ramps of 7.5% (1:13.3 or 1:13) is recommended....
- Figure 810.2.2 Dimensions of Bus Boarding and Alighting Areas – Drawing from the U.S. Access Board
-
Detectable Warnings on Curb Ramps
[See subsections ...]
- Designing Sidewalks and Trails for Access, Part II of II: Best Practices Design Guide
-
6 [§ 4.7.7]
6 [§ 4.7.7] Detectable warnings are dome-shaped bumps that should cover the entire width and depth of the ramp run....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an area...
-
1.1.14 Flatness of ramp cross slope
1.1.14 Flatness of ramp cross slope....
-
9 [§ 4.7.5]
9 [§ 4.7.5] Curb ramps either have flared sides or vertical edges called returned curbs....
-
11B-406.1 General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B-406....
-
11B-406.1 General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B-406....
-
11B-406.1 General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B-406....
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope....
-
4 [§ 4.7.2]
To measure the gutter slope, place the level in the same position as the arrow in the illustration, with one end where the gutter meets the ramp and the other end towards the street....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum....