The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
Search Results "Wheelchair Scale"
-
M303.2.5 Surfaces (Section-by-Section Analysis)
-
11B-604.8.1 Wheelchair accessible compartments
Wheelchair accessible compartments shall comply with Section 11B-604.8.1....
-
11B-604.8.1 Wheelchair accessible compartments
Wheelchair accessible compartments shall comply with Section 11B-604.8.1....
-
Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices: ADA Standard Section 206.2.9.2
Section 206.2.9.2 covers the ADA Standards for accessible routes to wheelchair spaces, ride seats designed for transfer and transfer devices in amusement rides.
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction....
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction....
- Welch Allyn Scale-Tronix® Integrated Scales
- Detecto FHD Series Stationary Wheelchair Scale
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with...
-
Figure M4: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and M304 Diagnostic Equipment for Use by a Patient in a Standing Position (Weight Scale Example)
The weight scale is usable by both people who are seated in wheelchairs and those who stand and must meet the requirements of both Sections M303 and M304. (M101.2)...
-
Wheelchair Spaces, Companion Seats, and Designated Aisle Seats: ADA Standard Section 802
Wheelchair spaces shall comply with 802.1....
- AccessRec WaterWheels® Floating Beach & Pool Chair
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramps M303:3.3, 3.3.1, 3.3.2 M303.3 Proposed Provision: Changes in Level at Entry to Wheelchair Spaces includes technical criteria for changes in level at the entry to a wheelchair space...
- Detecto 6550 Portable Wheelchair Scale
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces....
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations The Committee recommends standing supports located on one side of the platform,...
- seca 664 Digital Wheelchair Scale with Wireless Transmission
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...