Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
Search Results "Vertical Rod"
-
11B-307.4 Vertical clearance
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
407.8.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
-
407.12.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
-
407.8.3 Forward Reach
The vertical reference plane shall be centered, and intersect with, the operable part....
-
407.12.3 Forward Reach
The vertical reference plane shall be centered, and intersect with, the operable part....
-
406.4.1 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
-
406.4.1 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
- Installation Process of Genesis Vertical Platform Wheelchair Lift - Garaventa Lift
-
1017.9 Protruding Objects
However, entities should maintain the vertical clearance along the trail tread, resting intervals, and passing spaces free from tree branches for 80 inches high minimum above the ground....
-
407.12.3 Forward Reach (Section-by-Section Analysis)
The proposed provision would also require the vertical reference plane to be centered on, and intersect with, the operable part....
-
R402 Protruding Objects
R402 Protruding Objects
-
Head Room [4.3.5]
The 80 inch minimum vertical clearance applies not only to accessible routes but to all circulation routes (see 4.4.2)....
- Garaventa Elvoron CPL Vertical Platform Lift
-
Head Room [4.4.2]
Circulation paths must provide at least 80 inches of vertical clearance. Otherwise, fixed barriers detectable by canes must define areas with less clearance....
-
503.5 Vertical Clearance
503.5 Vertical Clearance....
- Garaventa Genesis Shaftway - Vertical Platform Lift
- Harmar RPL Residential Vertical Platform Lift
- Harmar EPL Enclosed Vertical Platform Lift
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum....
- Figure 307.4 Vertical Clearance – Drawing from the U.S. Access Board
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface....
-
5.4 Dining Areas
In non-elevator buildings, an accessible means of vertical access to the mezzanine is not required under the following conditions: 1) the area of mezzanine seating measures no more than...
-
M305.3.2 Vertical Position
Where the support is vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high maximum...