3.3.15 Reach...
Search Results "Unobstructed Reach"
-
3.3.15 Reach
-
Re: Section 307 Protruding Objects
Yes, it is a protruding object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant)...
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?
-
4.34.3(2)(b) Reach Depth More Than 10 in
(b) Reach Depth More Than 10 in (255 mm)....
-
2.2.3 Functional Reach
2.2.3 Functional Reach One-handed reach and lift capability data made at different heights, angles and object weights were collected in 3-D....
-
308.3.2 Obstructed High Reach
308.3.2 Obstructed High Reach....
-
308.3.2 Obstructed High Reach
The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
Golf Club Reach Range Area: ADA Standard Section 1007.3.2
Advisory 1007.3.2 Golf Club Reach Range Area. The golf club reach range applies to all holes required to be accessible....
-
Forward Reach [4.2.5]
Many people in wheelchairs may not be able to reach far beyond their toes. Forward reaches are measured to the edge of available clear floor space....
-
308.2 Forward Reach
308.2 Forward Reach....
-
R406 Reach Ranges
R406 Reach Ranges...
-
308.2 Forward Reach
308.2 Forward Reach....
-
308 Reach Ranges
308 Reach Ranges...
-
407.8.2 Side Reach
Operable parts of ICT providing a side reach shall conform to 407.8.2.1 or 407.8.2.2....
-
407.12.2 Side Reach
Operable parts of ICT providing a side reach shall conform to 407.12.2.1 or 407.12.2.2....
-
Maximum Depth: ADA Standard Section 306.2.2
Section 306.2.2 covers the current ADA Standards for the maximum depth for toe clearance.
-
Minimum Required Depth: ADA Standard Section 306.3.3
Section 306.3.3 covers the current ADA Standards for the minimum required depth for knee clearance.
-
Maximum Depth: ADA Standard Section 306.3.2
Section 306.3.2 covers the current ADA Standards for the maximum depth for knee clearance.
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-308.3.2 Obstructed high reach
The high side reach shall be 48 inches (1219 mm) maximum for a reach depth of 10 inches (254 mm) maximum....
-
Side reach (Section-by-Section Analysis)
Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3.1 reduce that maximum height to 48 inches....