(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
Search Results "Transfer Shower"
-
§ 35.151(e)(2)
-
4.21.4 Grab Bars
ADAAG specifies grab bars on the three walls of a roll-in shower stall, 33"-36" above the floor. The plans reviewed offered little insight as to placement of grab bars in showers....
-
11B-608.3.1 Reserved
[See subsections ...]
-
1g
g. Is there a horizontal grab bar on the wall opposite the seat as shown in Figure 37(a) above? [ADA Stds. 4.21.4; Fig. 37] Yes __ No __ N/A __ Comments:...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
4.21.5 Controls
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
4.21.5 CONTROLS
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
4.34.5.5 SHOWERS
If a shower is provided, it shall have the following features:...
-
Controls: ADA Standard Section 608.5
Section 608.5 covers the current ADA Standards for controls in shower compartments.
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
Transfer Height: ADA Standard Section 1002.5.2
The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
1j
Is there an adjustable height shower wand with at least a 60" long hose provided for persons who must shower from a seated position?...
- Willoughby Industries US-HC Cabinet Shower
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
11B-608.5.1 Reserved
[See subsections ...]