Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
Search Results "Tactile Exit Signage"
Commonly Searched Documents
-
Designations: ADA Standard Section 216.2
-
A4.30 Signage
[See subsections ...]
-
4.30 Signage
[See subsections ...]
-
4.30 SIGNAGE
[See subsections ...]
-
A.4.30 SIGNAGE
[See subsections ...]
- Access Board: Exit Signs
-
III-7.5165 Signage
IIIā7.5165 Signage (ADAAG §§4.1.3(16); 4.30.7)....
-
Permanent Rooms and Spaces
These types of signs are required to be tactile through the provision of braille and raised characters....
- Access Board: Tactile Sign Height
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
- Access Board: Tactile Sign Visual Requirements
- Access Board: Tactile Sign Location
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
4.1.2(7) Building Signage
(7) Building Signage. Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
703 Signs
The proposed rule specified that tactile signs, where required, meet specifications for both tactile and visual characteristics....
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...