Each exit door through a horizontal exit that is required to comply with Section 1013.1 shall be identified by a sign with the words, “TO EXIT.” ...
Search Results "Tactile Exit Signage"
-
1013.4, Item 5
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
1023.9 Stairway identification signs
The signage shall also state the story of, and the direction to, the exit discharge and the availability of roof access from the interior exit stairway and ramp for the fire department....
-
703 Signs
703 Signs
-
703.1 General
Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, shall...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
703.5 Visual Characters
703.5 Visual Characters. Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they...
-
703.5.1 Finish and Contrast
703.5.1 Finish and Contrast. Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark...
-
703.5.2 Case
703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both.
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
703.5.4 Character Proportions
703.5.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the...
-
703.5.5 Character Height
703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
-
703.5.6 Height from Finish Floor or Ground
703.5.6 Height from Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating...
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.5.8 Character Spacing
703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters...
-
703.5.9 Line Spacing
703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
III-7.5165 Signage
III−7.5165 Signage (ADAAG §§4.1.3(16); 4.30.7)....
-
SECTION 1013 EXIT SIGNS
-
1013.4 Raised character and braille exit signs
1013.4 Raised character and braille exit signs. [HCD 1-AC] Tactile exit signs shall be required at the following locations: 1....
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
11B-216 Signs.