902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
Search Results "Stream Height"
Commonly Searched Documents
-
902.3 Height
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
605.2 Height and Depth
605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use....
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5....
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground.
-
1008.2.5.3.2 Handrail Height
1008.2.5.3.2 Handrail Height. The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
(1) Adjustability: Minimum High Transfer Height
Another manufacturer gave examples of the height ranges of its beds and stretchers, each of which met the 25-inch minimum high height....
-
605.2 Height and Depth
[ECTCR UFAS 4.18.2] Figure 605.2 Height and Depth of Urinals...
-
902.4.2 Height
902.4.2 Height. The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
Transfer Height
Transfer Height Ride seats designed for transfer must be between 14 and 24 inches above the load and unload area surface....
- Pressalit Care Nursing bench 2000, electrically height adjustable
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
4.18.2 Height
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the finish floor.
-
4.18.2 HEIGHT
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the floor.
- Pressalit Care Adult changing table 3000, electrically height adjustable
-
EXHIBIT B
EXHIBIT B The average anthropometric dimensions employed shall be: (1) average eye height for a person sitting in a wheelchair is 47.45"; (2) horizontal distance from the eye of an average...
-
11B-605.2 Height and depth
11B-605.2 Height and depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B-605.2 Height and depth
FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS...
-
Check-out Aisle Counter Height
Under this requirement, the height of check-writing surfaces, where provided, is to comply with the height of work surfaces addressed in section 902.3 (34 inches maximum), consistent with...
-
Height
Height Where railings, guards, or handrails are provided on a fishing pier or platform, at least 25 percent of the rails must be 34 inches or less in height above the ground or deck...
-
604.9.3 Height
604.9.3 Height. The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....