ETA Editor's Note Stairway signage is among the most frequently-observed barriers in California, because of the prevalent misunderstanding of the requirements....
Search Results "Stair Signage"
-
1023.9 Stairway identification signs
-
1023.9 Stairway identification signs
ETA Editor's Note Stairway signage is among the most frequently-observed barriers in California, because of the prevalent misunderstanding of the requirements....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
4.1.2(15)
In addition, permanent signage that identifies rooms and spaces shall also comply with 4.30.4 and 4.30.6....
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
- Takeform Fusion Signage Miscellaneous Room Identification Type E
-
216 Signs
A new exception exempts signs in parking facilities from compliance with the signage provisions of section 216 except those covering means of egress (216.4) and designation of accessible...
-
Handrails: ADA Standard Section 1009.6.2
Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
Handrail extensions required by Section 11B-505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
Handrail extensions required by Section 11B-505.10.3 shall not be required on pool stairs....
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
- Takeform Fusion Signage Miscellaneous Room Identification Type E.3
-
ETA Summary of ADA Signage Requirements
Summary of ADA Signage Requirements Click here to view/download the pdf version (162 KB)....
-
Handrails: ADA Standard Section 504.6
Section 504.6 covers the current ADA Standards for handrails at stairways.
-
11B-504.6 Handrails
Stairs shall have handrails complying with Section 11B-505....
-
11B-504.6 Handrails
Stairs shall have handrails complying with Section 11B-505....
- How Blind People Find Braille Signs
-
ETA Summary of ADAAG/CBC Signage Requirements
ADAAG/CBC Signage Requirements Click here to view/download the pdf version (1.22 MB)...