[See subsections ...]
Search Results "Sleeping Compartment"
Commonly Searched Documents
-
11B-604 Water closets and toilet compartments
-
9.1.3 Sleeping Accommodations for Persons with Hearing Impairments
In addition to those accessible sleeping rooms and suites required by 9.1.2, sleeping rooms and suites that comply with 9.3 (Visual Alarms, Notification Devices, and Telephones) shall be...
-
11B-223.1.1.1 Area alterations
Patient bedrooms or resident sleeping rooms added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility shall...
-
11B-604.8.1 Wheelchair accessible compartments
Wheelchair accessible compartments shall comply with Section 11B-604.8.1....
-
11B-604.8.2 Ambulatory accessible compartments
Ambulatory accessible compartments shall comply with Section 11B-604.8.2....
-
11B-604.8.2 Ambulatory accessible compartments
Ambulatory accessible compartments shall comply with Section 11B-604.8.2....
-
11B-604.8.1 Wheelchair accessible compartments
Wheelchair accessible compartments shall comply with Section 11B-604.8.1....
-
608 Shower Compartments
608 Shower Compartments...
-
806.2.3 Sleeping Areas
806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
9.1.5. Alterations to Accessible Units, Sleeping Rooms, and Suites
When sleeping rooms are being altered in an existing facility, or portion thereof, subject to the requirements of this section, at least one sleeping room or suite that complies with the...
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
- 604.8.1.2 Toilet Compartment Self Closing Door
-
11B-605.4 Flush controls
Urinals provided in urinal compartments and with hand operated flush controls shall have the controls located on the open side of the urinal....
-
608.2 Size and Clearances for Shower Compartments
608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2....
-
Toilet Compartments
Toilet Compartments Baby changing tables are not prohibited from being located in wheelchair accessible toilet compartments; however, the minimum space required by TAS 604.8.1.1 for...
-
Flush Controls: ADA Standard Section 604.6
Section 604.6 covers the current ADA Standards for water closets flush controls.
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed....