Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
Search Results "Self-Closing Door"
-
11B-404.2.8.2 Spring hinges
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404....
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404....
-
Closers
Closers Automated door closing is addressed by the ANSI/BHMA standards....
-
H.7 - Are hand held devices (palm tops, cell phones) covered by Section 508?
Most hand held devices currently fall in the category of "self contained closed products." (See Section 1194.25 of the Access Board's standards)....
-
Closed-Circuit Telephone
A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility.
-
CLOSED-CIRCUIT TELEPHONE
[DSA-AC] A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility.
-
CLOSED-CIRCUIT TELEPHONE
[DSA-AC] A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility.
-
Doors
landings each side of doors 11B-404.2.4.4 Thresholds 11B-404.2.5 Doors in series 11B-404.2.6...
-
Doors
landings each side of doors 11B-404.2.4.4 Thresholds 11B-404.2.5 Doors in series 11B-404.2.6...
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
- Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors – Drawing from the U.S. Access Board
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Architect
The 4040XP provides adjustments for Position 1-6, has a range of interior and exterior door sizes it can work on....
-
Operation: ADA Standard Section 407.3.2
Section 407.3.2 covers the current ADA Standards for elevator door operations.
-
404.2.7 Door and Gate Hardware
404.2.7 Door and Gate Hardware. Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
404.2.7 Door and Gate Hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
404.2.7 Door and Gate Hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
411.1.1 Decoding of Closed Captions
Players and displays shall decode closed caption data and support display of captions....
-
Closed Functionality
Examples of ICT with closed functionality are self-service machines, information kiosks, set-top boxes, fax machines, calculators, and computers that are locked down so that users may not...