percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
Search Results "Offset Flange"
Commonly Searched Documents
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Power Chair
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Scooter
percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Manual Wheelchair
percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Scooter
users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
- Zurn Industries 1-1/4" P-Trap, Offset Strainer, and Protectors
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Manual Wheelchair
users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Scooter
the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Power Chair
users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset...
-
Library
Offset pivot hinge on door to library Large print books in the library Handrails at two height Evaporative cooler to save the energy used by air conditioners...
-
Can stair handrail extensions overlap door maneuvering clearances?
However, the door maneuvering clearance can be offset up to 8” from the face of the door to accommodate wall thickness, casework, handrails, moldings, and other elements at doorways....
- Stanley FBB 269 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 266 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 268 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 264 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
-
4.3.7 Clear Floor Space for Reaching
This offset should be used for locating the clear floor space in relationship to the target....
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
- Stanley F248 Standard Weight Plain Bearing “Swing Clear” Full Mortise Offset Door Hinge
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...