Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
Search Results "Exterior Ramp"
Commonly Searched Documents
-
11B-405.9 Edge protection
-
Ramp
Ramp - A walking surface that has a running slope of greater than 1:20....
-
Edge Protection: ADA Standard Section 405.9
Section 405.9 covers the current ADA Standards for edge protection at ramps.
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
- Figure 405.7 Ramp Landings – Drawing from the U.S. Access Board
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1007.7 Exterior area for assisted rescue
1007.7 Exterior area for assisted rescue. Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
217.4.4 Exterior Site Requirement
Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
Section G: Ramps
Complete a separate ramp form for each ramp, whether exterior or interior....
-
Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water.
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water.
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
Continuity: ADA Standard Section 505.3
Section 505.3 covers the current ADA Standards for the continuity of handrails.
-
1132A.2 Interior doors and secondary exterior doors
1132A.2 Interior doors and secondary exterior doors....
-
Ramps and Curb Ramps
[See subsections ...]
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
Boarding Piers at Boat Launch Ramps: ADA Standard Section 235.3
Section 235.3 covers scoping requirements in the current ADA Standards for boarding piers at boat launch ramps.
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
- Seating Solutions ADA Platforms, Ramps & Stairs
-
Top and Bottom Extension at Ramps: ADA Standard Section 505.10.1
Section 505.10.1 covers the current ADA Standards for the top and bottom handrail extensions at ramps.
-
1003.2.13.7.1 Openness
The exterior area of refuge shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases....