Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
Search Results "Exit Door"
Commonly Searched Documents
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1013.4, Item 3
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
Double-Leaf Doors and Gates: ADA Standard Section 404.2.2
Section 404.2.2 covers the current ADA Standards for double-leaf doors and gates that are part of an accessible route.
-
1003.2.13.2 Enclosed exit stairways
Section 1003.2.13.2 Change to read as shown: (E20-00) 1003.2.13.2 Enclosed exit stairways. ...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
Manual Doors, Doorways, and Manual Gates: ADA Standard Section 404.2
Section 404.2 covers the current ADA Standards for manual doors, doorways and manual gates that are part of an accessible route.
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
Door Swing: ADA Standard Section 803.3
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
1007.3 Enclosed exit stairways
Exceptions: Open exit stairways as permitted by Section 1019.1 are permitted to be considered part of an accessible means of egress....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
- SetonGlo™ ADA Braille Signs - Exit Route
-
11B-224.1.2 Guest room doors and doorways
Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
1013.4 Raised character and braille exit signs
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.” 2....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....