Surfaces of transfer walls shall not be sharp and shall have rounded edges....
Search Results "Control End Wall"
Commonly Searched Documents
-
11B-1009.4.4 Surface
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
Height
Height The transfer wall height must be 16 inches minimum to 19 inches maximum, measured from the deck....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
607.4.1.1 Back Wall
607.4.1.1 Back Wall....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-604.6 Flush controls
Flush controls shall be hand operated or automatic....
-
607.4.2.1 Back Wall
607.4.2.1 Back Wall....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
11B-607.4.1.1 Back wall
11B-607.4.1.1 Back wall....
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.2.1 Back wall
11B-607.4.2.1 Back wall....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
1. Faucet Controls
Are the tub faucet controls positioned between the center of the end wall and the open side of the tub so persons with disabilities may approach and adjust the controls before they transfer...