Van Accessible Parking Spaces [§502.1 - 502.5] At least one space for every 6 or fraction of 6 accessible spaces must be van accessible. Van spaces provide an additional 3...
Search Results "Centerline"
Commonly Searched Documents
-
Van Accessible Parking Spaces [§502.1 - 502.5]
-
Re: 604.2 Water Closet Location
-
Lavatories Adjacent to Partitions
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-604.9 Water closets and toilet compartments for children's use
SECTION TITLE NOTES 11B-604.9 Water closets and toilet compartments for children's...
-
Wall furr-out to support a grab bar when toilet is too far from the side wall
Here's a good example of one solution for a water closet that's too far from the adjacent side wall. Sometimes this solution is easier than moving the fixture when an offset flange...
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
Plan 3A: 12-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 1A: 13-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 1B: 13-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 6B: 12-Foot Wide Accessible Guest Room
• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 4B: 13-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 6A: 12-Foot Wide Accessible Guest Room
• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 3B: 12-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 4A: 13-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 5A: 13-Foot Wide Accessible Guest Room
• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Plan 2B: 13-Foot Wide Accessible Guest Room
603.2.2); • Turning space includes knee and toe clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper...
-
Re: American Standard AccessPRO Toilet
Production of the American Standard AccessPRO Toilet was discontinued, and the manufacturer says there is no replacement fixtures offered that provides ability to move laterally as...
-
Re: American Standard AccessPRO Toilet
Thanks for the heads up, Jonathan! We’ll be on the lookout for the Toto.