Plumbing protection shall comply with Section 11B-809.9.7.
Search Results "Bathing Room"
Commonly Searched Documents
-
11B-809.10.8.5 Plumbing protection
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
216.8 Toilet Rooms and Bathing Rooms
216.8 Toilet Rooms and Bathing Rooms....
-
F216.8 Toilet Rooms and Bathing Rooms
Where existing toilet rooms or bathing rooms do not comply with 603, directional signs indicating the location of the nearest toilet room or bathing room complying with 603 within the facility...
-
216.8 Toilet Rooms and Bathing Rooms
Where existing toilet rooms or bathing rooms do not comply with 603, directional signs indicating the location of the nearest toilet room or bathing room complying with 603 within the facility...
-
11B-216.8 Toilet rooms and bathing rooms
Where existing toilet rooms or bathing rooms do not comply with Section 11B-603, directional signs indicating the location of the nearest toilet room or bathing room complying with Section...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
Vanity Counter Top Space: ADA Standard Section 806.2.4.1
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
6.4 Patient Toilet Rooms
Where toilet/bath rooms are provided as a part of a patient bedroom, each patient bedroom that is required to be accessible shall have an accessible toilet/bath room that complies with 4.22...
-
11B-224.1.4 Guest room toilet and bathing rooms
Where toilet and bathing rooms are provided in guest rooms that are not required to provide mobility features complying with Section 11B-806.2, toilet and bathing fixtures shall only be...
-
11B-224.1.4 Guest room toilet and bathing rooms
Where toilet and bathing rooms are provided in guest rooms that are not required to provide mobility features complying with Section 11B-806.2, toilet and bathing fixtures shall only be...
-
11B-224.1.4 Guest room toilet and bathing rooms
Where toilet and bathing rooms are provided in guest rooms that are not required to provide mobility features complying with Section 11B-806.2, toilet and bathing fixtures shall only be...
-
Saunas and Steam Rooms: ADA Standard Section 241
Section 241 covers scoping requirements in the current ADA Standards for saunas and steam rooms.
-
General: ADA Standard Section 803.1
Dressing, fitting, and locker rooms shall comply with 803. Advisory 803.1 General....
-
11B-803.1 General
Dressing, fitting, and locker rooms shall comply with Section 11B-803. Advisory 11B-803.1 General....
-
11B-216.8 Toilet rooms and bathing rooms
Where existing toilet rooms or bathing rooms do not comply with Section 11B-603, directional signs indicating the location of the nearest toilet room or bathing room complying with Section...
-
11B-216.8 Toilet rooms and bathing rooms
Where existing toilet rooms or bathing rooms do not comply with Section 11B-603, directional signs indicating the location of the nearest toilet room or bathing room complying with Section...
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
Unisex Toilet Rooms
Comments advised revising requirements for unisex toilet and bathing rooms for greater consistency with model building codes....
-
11B-603.1 General
Toilet and bathing rooms shall comply with Section 11B-603....