Search Results "Audible Alarm"
Commonly Searched Documents
-
Fire Alarm Systems: ADA Standard Section 702
-
215 Fire Alarm Systems
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system....
-
907.5.2.3 Visible alarms
Exceptions: In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced...
- Federal Signal PS Series Push Button Stations Fire Alarm
-
907.5.2 Alarm notification appliances.
[See subsections ...]
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4....
-
Visual Alarms
Visual Alarms • Where audible fire alarms or emergency notification is provided, flashing lights are required in public and common use areas, including toilet and bath rooms, locker rooms...
-
907.2.6.1 Group I-2
Such detectors shall provide a visual display on the corridor side of each patient room and shall provide an audible and visual alarm at the nursing station attending each room....
-
4.28.3* VISUAL ALARMS
If provided, electrically powered internally illuminated emergency exit signs shall flash as a visual emergency alarm in conjunction with audible emergency alarms....
-
4.28.3* Visual Alarms
Visual alarm signal appliances shall be integrated into the building or facility alarm system....
-
Visual Alarms [4.28.3]
Visual Alarms [4.28.3] In general, it is not sufficient to install visual signals only at audible alarm locations....
-
907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
Visual Alarms
Error/Omission: No visual alarms are provided although an audible alarm system is installed....
- Honeywell Fire-Lite Alarm BG-12 Series
-
A4.28.3 VISUAL ALARMS
The specifications in this section do not preclude the use of zoned or coded alarm systems....
-
Transient Lodging: ADA Standard Section 215.4
Section 215.4 covers scoping requirements in the current ADA Standards for fire alarm systems in transient lodging.
-
Safety Considerations for Site Selection
Choose facilities that are protected by audible and visible fire alarms and a fire sprinkler system. The U.S. Fire Administration has a list of approved hotels and motels....
-
11B-702 Fire alarm systems
[See subsections ...]
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
Car Position Indicators [4.10.13]
Visual and audible signals that indicate car position are required. Verbal announcements are acceptable and can substitute for chimes or other audible signals....
- STI Stopper® Emergency Station, Push, Turn-to-Reset SS-2001E Fire Alarm
-
Activation: ADA Standard Section 809.5.1.2
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...