The lift platform (not including the entrance ramp) shall not deflect more than 3 degrees (exclusive of vehicle roll or pitch) in any direction between its unloaded position and its position...
Search Results "Vehicle Parking Area"
-
§ 38.23(b)(9) Platform deflection
-
Requirement for Van Spaces in All Types of Facilities
The requirement for van spaces applies to all types of facilities, including those that are the subject of special provisions, such as hospital outpatient facilities (208.2.1),...
-
806.2.1 Living and Dining Areas
Living and dining areas shall be accessible....
-
806.2.1 Living and Dining Areas
Living and dining areas shall be accessible....
-
208.1.1
208.1.1 The removal of architectural barriers from a parking facility in accordance with 28 C.F.R. Section 36.304 or with Section 553.508, F....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
Areas of Refuge (Section-By-Section Analysis and Response to Comments)
- Areas of refuge (areas with direct access to a stairway, and where people who cannot use stairs may await assistance during a emergency evacuation) will be required, as proposed, but the...
-
Connection: ADA Standard Section 810.2.3
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402....
-
11B-203.10 Raised refereeing, judging and scoring areas
11B-203.10 Raised refereeing, judging and scoring areas....
-
Employee Work Areas: ADA Standard Section 215.3
Section 215.3 covers scoping requirements in the current ADA Standards for fire alarm systems in employee work areas.
-
Problem Five
Problem Five: A large number of accessible parking spaces are provided, including van accessible spaces, at a school near the main building entrance....
-
11B-221.2.1.6 Specialty seating areas
In assembly areas, wheelchair spaces shall be provided in each specialty seating area that provides spectators with distinct services or amenities that generally are not available to other...
-
11B-221.2.1.6 Specialty seating areas
In assembly areas, wheelchair spaces shall be provided in each specialty seating area that provides spectators with distinct services or amenities that generally are not available to other...
-
Currently, the DCFC time limit is 30 minutes maximum. New larger battery capacity will take longer to get 80% charge – i.e. Chevy Bolt EV, Tesla Model 3, 2018 Nissan LEAF, etc. Can we reconsider the time limit?
Where DCFC or any other type of charging is intended for use longer than 30 minutes, EVCS may be provided in regular parking-style vehicle spaces....
-
11B-248 Common use areas and employee work areas
[See subsections ...]
-
810.2 Bus Boarding and Alighting Areas
810.2 Bus Boarding and Alighting Areas. Bus boarding and alighting areas shall comply with 810.2. Advisory 810.2 Bus Boarding and Alighting Areas....
-
The National Highway Traffic Safety Administration’s (NHTSA) motor vehicle safety regulations require that a wheelchair lift be tested to withstand a 600-pound load. If the manufacturer states that the design load is 800 pounds, can the transportation operator limit actual use to 600 pounds for safety reasons?
The 600-pound test required under NHTSA’s Federal Motor Vehicle Safety Standards (FMVSS) represents the minimum design load specified under 49 CFR Part 38....
-
106.5.10 Assembly Area
For the purposes of these requirements, assembly areas include, but are not limited to, classrooms, lecture halls, courtrooms, public meeting rooms, public hearing rooms, legislative chambers...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....