The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
Search Results "Elevator Pit"
-
11B-407.3.3.2 Contact
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-409.4.7.4 Cord
The telephone cord shall be 29 inches (737 mm) long minimum.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309.
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided.
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
5. Is a talk tube where two children talk to each other simultaneously considered one or two play components? If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?
If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?...
-
Additional Number and Types: ADA Standard Section 240.2.1.2
Section 240.2.1.2 covers scoping requirements in the current ADA Standards for additional number and types of ground level play components.
-
11B-240.2.1.2 Additional number and types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
-
11B-240.2.1.2 Additional number and types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story...