The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
Search Results "Door Clear Width"
-
11B-407.3.4 Door and signal timing
-
Guidelines for Requirement 7
The second set of specifications include clear space specifications for bathrooms with in-swinging doors and for bathrooms with outswinging doors....
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
Thresholds: ADA Standard Section 404.3.3
Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-226.4 Baby changing tables
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
10.3.1(19)
(19) Where provided, baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2. If...
-
Door and Gate Hardware [§404.2.7]
Door and Gate Hardware [§404.2.7] Door and gate hardware must: allow one-hand operation not require tight grasping, pinching, or twisting of the wrist operate...
-
404.2.10 Door and Gate Surfaces
404.2.10 Door and Gate Surfaces....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
304.4 Door Swing
304.4 Door Swing. Doors shall be permitted to swing into turning spaces....
-
305 Clear Floor or Ground Space
305 Clear Floor or Ground Space...
-
Single-User Toilet Rooms: Side Transfer Space
Clear floor space should be centered at lavatories. This clear floor space, which can overlap space required at water closets, must extend 17 to 19 inches below the lavatory....
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
8.2 Reading and Study Areas
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and...