Satin finish stainless steel Model 4731-15 available BradEX 4731-15 recess mounted, serves a single end compartment...
Search Results "Compartment Depth"
Commonly Searched Documents
- Bradley Standard Series Napkin Disposal 4731-15
- 
    
  
  11B-408.4.1 Car dimensions and doors
  Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum.... 
- 
    
  
  Automated Revolving Doors
  Environments Laboratory (1993)) indicates that automated revolving doors, in order to be wheelchair accessible, must have a diameter of at least 10 to 12 feet depending on the number of compartments... 
- 
    
  
  305.7.2 Parallel Approach
  Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach... 
- 
    
  
  305.7.1 Forward Approach
  Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach... 
- 
    
  
  R404.7.1 Forward Approach
  The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft).... 
- 
    
  
  R404.7.2 Parallel Approach
  The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft).... 
- 
    
  
  4.34.6.5(3)
  (3) The depth of a sink bowl shall be no greater than 6-1/2 in (165 mm). Only one bowl of double- or triple-bowl sinks needs to meet this requirement.... 
- 
    
  
  § 38.111(a)(6)
  (6) Sleeper cars shall comply with §§38.113 (b) through (d), 38.115 through 38.121, and 38.125, of this part, and have at least one compartment which can be entered and used by a person... 
- 
    
  
  § 38.93(a)(1)
  (1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided... 
- 
    
  
  Side Entry: ADA Standard Section 1002.4.4.2
  For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering... 
- 
    
  
  11B-1002.4.4.2 Side entry
  For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering... 
- 
    
  
  11B-305.7.2 Parallel approach
  Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH... 
- 
    
  
  11B-305.7.1 Forward approach
  Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH... 
- 
    
  
  11B-213.3.4 Lavatories
  Where lavatories are provided, at least 10 percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment.... 
- 
    
  
  Door Maneuvering Clearance
  At doors that provide a latch side approach, the minimum depth of this clearance is increased where a closer is provided because additional space is needed to counteract the force of closers... 
- 
    
  
  § 38.23(c)(7) Stowage
  A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps, including portable ramps stowed in the passenger area, do not impinge on a passenger's... 
- 
    
  
  § 38.159(c)(7) Stowage
  A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps, including portable ramps stowed in the passenger area, do not impinge on a passenger's... 
- 
    
  
  305.7.1 Forward Approach
  Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach... 
- 
    
  
  305.7.2 Parallel Approach
  Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach... 
- 
    
  
  11B-705.1.2.4 Bus stops
  warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth... 
- 
    
  
  Approach and Maneuvering Clearance [§305.6 and §305.7]
  Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering.... 
- 
    
  
  11B-705.1.2.4 Bus stops
  warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth... 
- 
    
  
  1009.5.1 Transfer Platform
  Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ... 
