The bench shall be mounted 17 in to 19 in (430 mm to 485 mm) above the finish floor....
Search Results "Urinal Clear Floor Space"
-
4.35.4 Bench
-
403.5.3 Passing Spaces
403.5.3 Passing Spaces. An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4....
-
A4.2.1(3) Space Requirements for Passing
(3) Space Requirements for Passing....
-
A4.2.1(3) Space Requirements for Passing
(3) Space Requirements for Passing....
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
Toilet Compartments
Toilet Compartments Baby changing tables are not prohibited from being located in wheelchair accessible toilet compartments; however, the minimum space required by TAS 604.8.1.1 for...
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
R404.7.1 Forward Approach
The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
1015.3 Viewing Space
Each distinct viewing location shall provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
1015.3 Viewing Space
Each distinct viewing location shall provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
ยง 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
Water Closet Clearance
To allow greater transfer options, including side transfers, the 2010 Standards prohibit lavatories from overlapping the clear floor space at water closets, except in covered residential...
-
605.4 Flush Controls
Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
-
605.4 Flush Controls
Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
-
605.4 Flush Controls
605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
-
L. Lavatory
wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top of the bowl no higher than 34" above the floor...