(7) Handrails shall not rotate within their fittings.
Search Results "Perpendicular Curb Ramp"
Commonly Searched Documents
-
4.8.5(7)
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
B5. Curb Ramp
Is a curb ramp provided between the vehicle pull up area and the access aisle (see figure above) or the access aisle and the accessible route (see figure on page 9) to the accessible entrance...
-
§ 38.95(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
Play Components: ADA Standard Section 1008.4
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
5.8.1.2.1 Ramped Entry Slope Recommendations
5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the slope...
-
11B-1008.4 Play components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with Section 11B-1008.4....
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
-
10.2.1(1)
(1) Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96...
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
§ 38.95(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates stowed in the passenger...
-
Section A: Parking
(Note: Curb ramps may not be part of an access aisle since they include slopes greater than 1:48.) (§502.4) A5 Are the surfaces of the designated...
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
M303.3.3 Ramped (Section-by-Section Analysis)
The commenter, a medical association, concurred with the requirement for handrails on diagnostic equipment with ramps over six inches in height....
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
1011.4, Item 2.2
2.2 “EXIT RAMP DOWN”...
-
1011.4, Item 2.4
2.4 “EXIT RAMP UP”...
-
1013.4, Item 2.2
“EXIT RAMP DOWN”...
-
1013.4, Item 2.4
“EXIT RAMP UP”...