Button spacing shall comply with Section 11B-407.4.7.1.5.
Search Results "Elevator Hoistway"
Commonly Searched Documents
- 
    
  
  11B-411.4.7.4 Button spacing
  
 - 
    
  
  11B-411.4.6.1 Location
  
Controls shall be located within one of the reach ranges specified in Section 11B-308.
 - 
    
  
  11B-407.4.6.2.4 Operation
  
Car control buttons shall be activated by a mechanical motion that is detectable.
 - 
    
  
  11B-407.4.10.3 Structural strength
  
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
 - 
    
  
  11B-407.4.10.1 Location
  
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
 - 
    
  
  11B-407.4.10.2 Surfaces
  
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
 - 
    
  
  11B-411.4.7.1 Type
  
Control button type shall comply with Section 11B-407.4.7.1.1.
 - 
    
  
  1009.4.1 Standby power
  
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
 - 
    
  
  11B-407.4.7.1.3 Symbols
  
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP...
 - 
    
  
  407.4.7.1.3 Symbols
  
Table 407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP...
 - 
    
  
  [F] 907.5.2.3 Visible alarms
  
Visible alarm notification appliances shall not be required in elevator cars....
 - 
    
  
  11B-407.4.7.1.3 Symbols
  
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop...
 - 
    
  
  11B-407.4.7.1.3 Symbols
  
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop...
 - 
    
  
  Verify Electrical
  
11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls. 11B-308 Location of elevator...
 - 
    
  
  Verify Electrical
  
11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls. 11B-308 Location of elevator...
 - 
    
  
  11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
  
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
 - 
    
  
  407.4.7.1.3 Symbols
  
[ECTCR UFAS 4.10.12(2), Fig. 23(a)] Table 407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency...
 - 
    
  
  General: ADA Standard Section 213.1
  
Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for toilet facilities and bathing facilities.
 - 
    
  
  Transfer Platforms: ADA Standard Section 1008.3.1
  
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1.
 - 
    
  
  11B-1008.3.1 Transfer platforms
  
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1.
 - 
    
  
  1.9.1.2.2
  
1.9.1.2.2 Any sanitary facilities which are made available for the public, clients or employees in such accommodations or facilities.
 - 
    
  
  11B-213.1 General
  
Where toilet facilities and bathing facilities are provided, they shall comply with Section 11B-213. Where toilet facilities and bathing facilities are provided in facilities...
 - 
    
  
  11B-411.4.7.3 Symbols
  
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.
 - 
    
  
  1.9.1.2.1
  
1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1. The term "used by the...