Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
Search Results "Elevator Hall Call Button"
Commonly Searched Documents
- 
    
  
  11B-407.4.7.1.1 Type
  
 - 
    
  
  11B-408.4.6 Car controls
  
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  11B-408.4.6 Car controls
  
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  11B-408.4.6 Car controls
  
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  11B-407.4.7.1.1 Type
  
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
 - 
    
  
  408.4.6 Car Controls
  
Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall....
 - 
    
  
  4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
  
Elevator doors shall open and close automatically....
 - 
    
  
  407.3.5 Door Delay
  
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
 - 
    
  
  407.3.5 Door Delay
  
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
 - 
    
  
  Leveling: ADA Standard Section 409.4.4
  
Section 409.4.4 covers the ADA Standards for the self-leveling feature in private residence elevators.
 - 
    
  
  11B-407.4.3 Platform to hoistway clearance
  
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
 - 
    
  
  11B-411.4.7.2 Location
  
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
 - 
    
  
  11B-407.4.8.2 Audible indicators
  
Audible indicators shall comply with Section 11B-407.4.8.2.
 - 
    
  
  11B-409.4.4 Leveling
  
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
 - 
    
  
  407.4.8.2.1 Signal Type
  
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
 - 
    
  
  407.3.5 Door Delay
  
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
 - 
    
  
  407.4.8.2.1 Signal Type
  
[ECTCR UFAS 4.10.13] EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with...
 - 
    
  
  407.4.8.2.1 Signal Type
  
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
 - 
    
  
  409.4.6.2 Location
  
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
 - 
    
  
  11B-409.4.6.2 Location
  
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
 - 
    
  
  11B-409.4.6.2 Location
  
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
 - 
    
  
  1008.2.1 Ground Level and Elevated Play Components
  
1008.2.1 Ground Level and Elevated Play Components....
 - 
    
  
  4.1.6(3)(c)(iii)
  
(iii) Equivalent facilitation may be provided with an elevator car of different dimensions when usability can be demonstrated and when all other elements required to be accessible comply...
 - 
    
  
  1008.2.1 Ground Level and Elevated Play Components
  
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the...