Section 404.2.9 addresses the opening force of doors and gates....
Search Results "Door Clear Width"
Commonly Searched Documents
-
Opening Force
-
Accessible Room Set-Up
Accessible Room Set-Up Once an accessible site is selected, it is essential that the meeting room furniture be arranged to allow everyone to fully participate. An accessible floor...
-
Accessible Routes (Exterior and Interior)
Once a voter with a disability arrives at the polling site, there must be an accessible route from the accessible parking, passenger drop-off sites, sidewalks and walkways, and...
-
403.5 Clearances
Walking surfaces shall provide clearances complying with 403.5. EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be...
-
403.5 Clearances
Walking surfaces shall provide clearances complying with 403.5. EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be...
-
Accessible Routes - Interior and Exterior
Accessible Routes - Interior and Exterior Common Problem: Both the exterior pedestrian routes (e.g., sidewalks, walkways and plazas) on a site that people use to travel from...
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Alterations and Water Closet Clearances in Single-User Toilet Rooms With In-Swinging Doors (Section-by-Section Analysis)
The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
-
Door stop
[See subsections ...]
-
11B-404 DOORS, DOORWAYS, AND GATES
[See subsections ...]
-
Common Questions (Entrances, Doors, and Gates)
Common Questions
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
Clear space
Clear space: A grid 72 inches long by 90 inches wide was used to facilitate the recording of space requirements for each WMD user (Figure 1)....
-
Accessible entrances that have turnstiles must provide an accessible gate or door.
• Accessible entrances that have turnstiles must provide an accessible gate or door....
-
1132A.10 Door signal devices
1132A.10 Door signal devices. Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
Can doors swing into turning space?
Yes, doors can swing into turning space....
-
11B-502.2 Vehicle spaces
Car parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent...
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
H. Door Maneuvering Clearance
On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor...
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
4.8.2 Clear Floor or Ground Space
The clear floor or ground space around outdoor rinsing showers shall be 60 inches (1525 mm) by 60 inches (1525 mm)....