Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting...
Search Results "Standing Support"
-
609.8 Structural Strength
-
Q: What is VCO? Who uses it?
VCO can be accomplished with standard stand-alone TTY equipment simply by having the call taker alternate between listening on the handset when the caller is speaking and placing the handset...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
Play Components
Play components may be manufactured or natural, and may be stand alone or part of a composite play structure....
-
E2-1. Pedestrian Routes
[ADA Stds. 4.4] Note: These objects may be wall mounted or free standing....
-
R402.3 Post-Mounted Objects
Where objects are mounted on free-standing posts or pylons and the objects are 685 mm (2.25 ft) minimum and 2030 mm (6.7 ft) maximum above the finish surface, the objects shall overhang...
-
Den
Closet with clothing storage for both standing and seated users....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
M302.1 General
Diagnostic equipment that supports patients in a seated position shall comply with M302. ...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
§ 1194.2(a)(2)
(2) When procuring a product, if an agency determines that compliance with any provision of this part imposes an undue burden, the documentation by the agency supporting the procurement...
-
4.26.3(3)
Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting device or the supporting...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Figure 20: Deaf-blind user stands with his hand on the original APS to feel the vibration in order to know when to begin to cross....
-
Devices or Methods for Notification of Other Emergencies
Guests who are deaf or hard of hearing are provided with small teleprompter-type screens mounted on small stands....
-
M301.1 General
Diagnostic equipment that supports patients in a supine, prone, or side-lying position shall comply with M301. ...
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
4.26.3(4)
a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable withdrawal load between the fastener and the supporting...
-
410.6 Real-Time Text Functionality (Section-by-Section Analysis)
Proposed 410.6 would require that, where ICT supports real-time voice communication, it must also support RTT functionality....
-
C.
The Department argues that Executive Order 13217, which directs the Attorney General to "fully enforce Title II of the ADA," supports its authority to bring suit. Exec....
-
5.8.2.4 Unobstructed Floor Space Recommendation
The base support affects how close the patient can get to the mammography machine because it intrudes into the floor space....