Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall...
Search Results "Side Reach"
Commonly Searched Documents
-
11B-809.10.7.3 Reinforcement for grab bars
-
Measuring Techniques
Reach For reach and field-of-vision measurements, Air Force methodology is, once more, instructive....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2.1 Clearance
[2010 ADA Standards] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the...
-
Dyson Airblade V Hand Dryer Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Towel Dispenser 250-15 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley MG Terreon Waste Receptacle Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
Transfer Space: ADA Standard Section 1008.3.1.3
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.2.3
Section 608.2.3 covers the current ADA Standards for the size and clearances of alternate roll-in type shower compartments.
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-704.4.1 Height
accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side...
-
III-7.5185 Automated teller machines
The ADAAG standard now in effect provides that ATM's must meet the requirements for both a forward and a side approach....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
UDI
Reach measurements were obtained without touching the individual. Reaching abilities were measured both with and without “bending” although a definition of “bending” was not provided....
-
Transfer Space: ADA Standard Section 1009.5.2
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-1009.5.2 Transfer space
by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
Location: ADA Standard Section 604.2
Section 604.2 covers the current ADA Standards for the mounting location of water closets.
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory 11B-221.2.3.1 Horizontal dispersion....
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
Range or Cooktop: ADA Standard Section 804.6.4
The location of controls shall not require reaching across burners....