In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
Search Results "Residential Amenity Center"
Commonly Searched Documents
-
604.5 Grab Bars
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
- From the ACTCP Program: "ADA Now: Small Businesses and the ADA" Publication
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
The following may only be used for determining required access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult...
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
1133A.7, Item 3
3. A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm).
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
1133A.7, Item 3
3. A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm).
-
11B-809.9.2 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work...
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5.
- Harmar RPL Residential Vertical Platform Lift
-
Elevator Exception 1—Section 206.2.3 of the 2010 Standards
., a shopping center, a shopping mall, the professional office of a health care provider, etc.)....
-
F206.2.3 Multi-Story Buildings and Facilities
In residential facilities, an accessible route shall not be required to connect stories where residential dwelling units with mobility features required to comply with 809.2 through 809.4...
-
Tips for Weighing People Using an Accessible Scale
By June Isaacson Kailes, Associate Director Harris Family Center for Disability and Health Policy Western University of Health Sciences, Pomona, California Update - 12.30.16...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the...
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm)...
-
Guidelines for Environmental Infection Control in Health-Care Facilities (excerpts related to service animals only)
Department of Health and Human Services Centers for Disease Control and Prevention (CDC) 2003 Last update: February 15, 2017 * * * * * * ...
-
11B-205.1 General
In residential dwelling units with mobility features where receptacles are provided in a kitchen at a corner work surface, one receptacle shall be located 36 inches (915 mm) from either...
- Case Law/Legal Briefs compiled by the Southeast ADA Center