In the 2010 NPRM, the Board proposed to retain the existing requirement that ramps and bridgeplates longer than 30 inches (as well as lifts) be required to have design loads of 600 pounds...
Search Results "Portable Patient Lift"
Commonly Searched Documents
-
T402 Ramps and Bridgeplates
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
C. Communication Features
(Note: In the guestrooms/suites, this requirement may be satisfied by either a fixed strobe unit hardwired to the building-wide fire alarm system, or by a kit which contains a portable strobe...
-
§ 38.25(b) Contrast
All step edges, thresholds and the boarding edge of ramps or lift platforms shall have a band of color(s) running the full width of the step or edge which contrasts from the step tread and...
-
A. Accessible Voting Program
The County shall maintain in operable working condition on Election Day those features of facilities and equipment (including, but not limited to, both permanent equipment such as lifts...
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
-
Figure M1: Overview of M301 Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position
[See subsections ...]
-
M305.2.5 Surface Hazards
Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges.
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
M305.2 Transfer Supports (Section-by-Section Analysis)
This is an introductory section. As discussed above in Section IV.E.1. (Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and...
-
5.4 Transfer Supports
5.4 Transfer Supports.
-
5.4 Transfer Supports Recommendations
5.4 Transfer Supports Recommendations
-
M305.2 Transfer Supports
Transfer supports shall comply with M305.2.
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
In the MDE NPRM, the transfer side provision for diagnostic equipment used by patients in the seated position required transfer surfaces to have the option to transfer from a mobility device...
- SafePath: Threshold Ramp Installation for MultiFamily Housing for Disability Access
- SafePath: ADA Entry Level Landing Installation Training Video
-
Section 35.151(h) Medical care facilities
The language used in this rule (“in a manner that is proportionate by type of medical specialty’’) is more specific than that used in the NPRM (“in a manner that enables patients with disabilities...
-
Section 36.406(g) Medical Care Facilities
The language used in this rule (“in a manner that is proportionate by type of medical specialty’’) is more specific than that used in the NPRM (“in a manner that enables patients with disabilities...
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.2.3 Size
The size of the transfer surface shall comply with M301.2.3.1 or M301.2.3.2. The size of transfer surfaces shall be measured from center points of their opposing sides.
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum. (proposed...