As part of the initial design and construction, for example, structural backing would be provided for the later installation of grab bars, base cabinets under kitchen sinks would be removable...
Search Results "Military Installation"
-
ADAPTABLE
-
§27.71(j)(1)
(1) Airport operators that jointly own, lease, or control automated airport kiosks with carriers at U.S. airports must ensure that all shared-use automated kiosks installed on or after December...
-
§ 27.71(j)(1)
(1) Airport operators that jointly own, lease, or control automated airport kiosks with carriers at U.S. airports must ensure that all shared-use automated kiosks installed on or after December...
-
907.2.1 Group A
A manual fire alarm system shall be installed in accordance with NFPA 72 in Group A occupancies having an occupant load of 300 or more....
-
711.4.1.2 Through-penetration firestop system
Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814, with a minimum positive pressure differential...
-
A4.31.3 Mounting Height
A generally available public telephone with a coin slot mounted lower on the equipment would allow universal installation of telephones at a height of 48 in (1220 mm) or less to all operable...
-
Intensity
or its reflection from adjacent walls and ceiling) must be of an intensity that will raise the overall light level sharply, but not be so intense as to be unsafe for direct viewing when installed...
-
R308.1 Transit Stops
Where security bollards are installed at transit stops, they must not obstruct the clear space at boarding and alighting areas or reduce the required clear width at pedestrian access routes...
-
Door Protective and Reopening Device [4.10.6]
Door safety edges, used alone as the reopening device, are permitted only in alterations where installation of an automatic reopening device is not technically feasible....
-
A4.31.3 MOUNTING HEIGHT
A generally available public telephone with a coin slot mounted lower on the equipment would allow universal installation of telephones at a height of 48 in (1220 mm) or less to all operable...
-
PLATFORM
A temporary platform is one installed for not more than 30 days....
-
11B-705.3 Product Approval
Only approved DSA-AC detectable warning products and directional surfaces shall be installed as provided in the California Code of Regulations (CCR), Title 24, Part 1, Chapter 5, Articles...
-
11B-608.5.1 Reserved
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
PLATFORM
A temporary platform is one installed for not more than 30 days....
-
11B-225.2 Storage
Where provided, at least one of each type of storage must be within the reach ranges specified in Section 11B-308; however, it is permissible to install additional storage outside the reach...
-
Section 36.303(g)(7) Compliance Date for Providing Captioning and Audio Description
Although the Department expressed the belief that 6 months was sufficient time for movie theaters to order and install the necessary equipment, train employees on how to use the equipment...
-
1.2.2 Alternative materials, design and methods of construction and equipment
The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided...
-
[2010 ADAS] 105.2.5 NFPA
NFPA 72-1999 and NFPA 72-2002 address the application, installation, performance, and maintenance of protective signaling systems and their components....
-
1007.3 Stairways
Exceptions: The clear width of 48 inches (1219 mm) between is not required in buildings equipped throughout with an installed in accordance with Section 903.3.1.1 or 903.3.1.2....
-
1136A.1 Receptacle heights
Exceptions: Receptacle outlets installed as part of permanently installed baseboard heaters are exempt....
-
Flush Controls on Toilets
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
Exterior Telephones
Some commenters seemed unclear on whether requirements for wheelchair access applied to exterior installations. Response....
-
7(2)(b)(vii)
facility provided in the covered dwelling unit, or on the accessible level of a covered multistory unit, and measures a nominal 36 x 36, the shower stall must have reinforcing to allow for installation...
-
Keep Good Notes
If there isn’t an accessible entrance you’ll want to indicate how many steps there are and how much space is available to install a ramp or lift....