Car control buttons shall comply with Section 11B-407.4.7.1.
Search Results "Destination-Oriented Elevator"
Commonly Searched Documents
-
11B-407.4.7.1 Buttons
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-407.4.7.1 Buttons
Car control buttons shall comply with Section 11B-407.4.7.1.
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation. Signs shall be...
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated.
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable.
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
-
11B-407.4.10.2 Surfaces
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
1009.4.1 Standby power
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
-
11B-407.4.7.1.3 Symbols
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP...
-
407.4.7.1.3 Symbols
Table 407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP...
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in elevator cars....
-
11B-407.4.7.1.3 Symbols
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop...
-
11B-407.4.7.1.3 Symbols
TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop...
-
Verify Electrical
11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls. 11B-308 Location of elevator...
-
Verify Electrical
11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls. 11B-308 Location of elevator...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
407.4.7.1.3 Symbols
[ECTCR UFAS 4.10.12(2), Fig. 23(a)] Table 407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency...