Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
Search Results "Sink Height"
Commonly Searched Documents
-
11B-809.10.8.1 Location
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters indicating elevator car controls shall not be...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
11B-805.4.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room. ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has...
-
11B-805.4.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room. ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has...
-
11B-805.4.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room. ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has...
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
IV. ACCESSIBLE MEDICAL EQUIPMENT
Subsequent Height-Adjustable Equipment Purchases....
-
4.17.6 Grab Bars
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided. Grab bars may be mounted with any desired method as long as they have a...
-
Telescopes and Periscopes
Viewing areas are sometimes equipped with mounted telescopes or periscopes to provide the visitor with a better view of a point of interest. Whenever a telescope or periscope is...
-
4.9.4 HANDRAILS
Stairways shall have handrails at both sides of all stairs. Handrails shall comply with 4.26 and shall have the following features: (1) Handrails shall be continuous along both...
-
4.17.6 GRAB BARS
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided. Grab bars may be mounted with any desired method as long as they have a...
-
4.8.5* HANDRAILS
If a ramp run has a rise greater than 6 in (250 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides. Handrails are not required on...
- McGuire Manufacturing Co., Inc. Heavy Finish Offset Lavatory Strainer
- McGuire Manufacturing Co., Inc. 155WC: Offset Lavatory Strainer
- IPS Corporation Truebro® Lav Shield® Protective Lavatory Enclosure
- McGuire Manufacturing Co., Inc. ProDrainWC: Lavatory Strainer Less Overflow
- Figure 407.2.3.2 Car Designations on Jambs of Destination-Oriented Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
ADA Compliant Plumbing Products for Accessible Kitchens and Baths - CEU Course
Ergonomics. Technology. ADA regulations. The delivery of water raises a variety of design issues and opportunities. Delta Faucet Company now offers several AIA-approved...
-
703.5.9 Line Spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....