The width of elevator doors shall comply with Table 407.4.1....
Search Results "Non-Elevator Building"
-
407.3.6 Width
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADA Standards] 407.3.5 Door Delay....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADA Standards] 407.3.5 Door Delay....
-
Example: Town Library is a Historic Property
architect to determine if an accessible entrance can be provided and is told that a ramp or lift cannot be added to either entrance without a significant change to the exterior of the building...
-
C. Chapter 2: Scoping Requirements
Chapter 2 in the 2016 Non-Rail Vehicle Guidelines has been substantially reorganized to present a more simplified approach....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
Section 100.205(c)(3)(ii) requires that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
Ground Level and Elevated Play Components: ADA Standard Section 206.2.17.1
Section 206.2.17.1 covers scoping requirements in the most current ADA Standards for accessible routes to ground level and elevated play components.
-
Car Position Indicators [§407.4.8]
Car Position Indicators [§407.4.8] Position indicators are required for all cars, including those of 2-stop elevators....
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
[2010 ADAS] 105.2.4 ICC/IBC
International Building Code, 2000 Edition (see 207.1, 207.2, 216.4.2, 216.4.3, and 1005.2.1). International Building Code, 2001 Supplement (see 207.1 and 207.2)....
-
Alterations to Qualified Historic Buildings and Facilities: ADA Standard Section 202.5
Section 202.5 covers the most current ADA Standards for alterations to qualified historic buildings and facilities.
-
Height: ADA Standard Section 1005.2.1
EXCEPTION: Where a guard complying with sections 1003.2.12.1 and 1003.2.12.2 of the International Building Code (2000 edition) or sections 1012.2 and 1012.3 of the International Building...
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...