Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
Search Results "Non-Elevator Building"
Commonly Searched Documents
-
407.4.6.1 Location
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console. ...
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
4.1.6(1)(k)(ii)
For example, alterations to floors above or below the ground floor must be accessible regardless of whether the altered facility has an elevator....
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
- GameTime Hex Deck with Shadow Play Flower
-
11B-217.4.3.2 Private buildings
Where four or more public pay telephones are provided in a private building, at least one public TTY shall be provided in the building....
-
11B-217.4.3.2 Private buildings
Where four or more public pay telephones are provided in a private building, at least one public TTY shall be provided in the building....
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface...
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....