Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
Search Results "Fundamental Alteration"
Commonly Searched Documents
-
11B-404.2.3 Clear width
-
Accessible Path of Travel
When alterations are made to a primary function area, an accessible path of travel to the area must be provided....
-
404.2.3 Clear Width
In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
11B-404.2.3 Clear width
In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop. 2. ...
-
404.2.3 Clear Width
In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
1. My business does not need to be compliant because the building is old and therefore is grandfathered.
If your facility was built or had any alterations made to it since January 26, 1992 (under the ADA) or was built or had any alterations made to it since 1970 (under California law), there...
-
IV. Deeming 2010 Standards as an Alternative Accessibility Standard for Section 504 Compliance
For purposes of Section 504 compliance, this does not mean that existing buildings that are part of a project and which are not being altered must be brought up to the 2010 Standards....
-
B. 2004 ADA and ABA Accessibility Guidelines
Until HUD adopts a new accessibility standard, HUD recipients who undertake alterations or new construction of a project may continue to utilize UFAS and HUD’s Section 504 or ABA regulations...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
11B-213.2 Toilet rooms and bathing rooms
In alterations where it is technically infeasible to comply with Section 11B-603, altering existing toilet or bathing rooms shall not be required where a single unisex toilet room or bathing...
-
4.1.6(4)(f)
(i) In alterations where it is structurally impracticable to disperse seating throughout the assembly area, seating may be located in collected areas as structurally feasible....
-
11B-213.2 Toilet rooms and bathing rooms
In alterations where it is technically infeasible to comply with Section 11B-603, altering existing toilet or bathing rooms shall not be required where a single unisex (single-user or family...
-
Sec.36.308(a)(3)
(3) The requirements of paragraph (a) of this section shall not be interpreted to exceed the standards for alterations in subpart D of this part....
-
ADA & Level Boarding - When Does Section 37.42 begin to apply?
49 CFR §37.42(a) DECEMBER 14, 2011
-
4.1.6(1)(b)
(b) If power-driven vertical access equipment (e.g., escalator) is planned or installed where none existed previously, or if new stairs (other than stairs installed to meet emergency...
-
Scoping Requirements
[See subsections ...]
-
1009.1 Accessible means of egress required
Accessible means of egress shall comply with this section. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress...
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 213.2
Section 213.2 covers scoping requirements in the current ADA Standards for toilet rooms and bathing rooms.
-
F210.1 General
In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when...
-
210.1 General
In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when...