There are hard-wired systems and three types of wireless systems: induction loop, infrared, and FM radio transmission....
Search Results "Emergency Call System"
Commonly Searched Documents
-
706.1 General
-
1009.5.1 Transfer Platform
A transfer platform shall be provided at the head of each transfer system....
-
8. Reservations Made by Places of Lodging
guest rooms for people with disabilities until all other guest rooms of that type have been rented, and to ensure that a reserved accessible guest room is removed from all reservations systems...
-
407.2.2.2 Visible Signals
Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1....
-
407.2.2.2 Visible Signals
Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1....
-
Technical Memorandum TM 2012-02 Emergency Response Buildings and Facilities
TM 2012-02 Emergency Response Buildings and Facilities Effective Date: November 15, 2012 2012 TAS Reference: 233 and 809 Based on information received from the U.S....
-
Features of the ETA Standard Barrier Survey/Barrier Management System [Title III]
The ETA ADA Barrier Management System The ETA ADA Barrier Management System’s reports facilitate your management of identified barriers, assist you in setting priorities, allow tracking...
-
Same Management or Building
receivers required based on the total number of seats in all the assembly areas, instead of each assembly area separately, where the receivers are compatible with the assistive listening systems...
-
11B-219.4 Location
If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area...
-
11B-219.4 Location
If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area...
-
11B-219.4 Location
If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area...
-
Features of the ETA Standard Barrier Survey/Barrier Management System [Title II]
The ADA Barrier Management System The ADA Barrier Management System’s reports facilitate your management of identified barriers, assist in setting priorities, allow tracking of barrier...
-
Car Controls [4.10.12]
indication does not have to be provided by the button itself (jeweled lights beside buttons are permitted but cannot interfere with the placement of raised and Braille characters) emergency...
-
407.2.2.2 Visible Signals
Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1....
- Pushbutton Transmitter (BE1240)
-
Ground Level and Elevated Play Components: ADA Standard Section 1008.2.1
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the...
-
11B-1008.2.1 Ground level and elevated play components
Exceptions: Transfer systems complying with Section 11B-1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided...
-
§ 38.53(a)(2)
aid users can be accommodated, then such doorway shall have a minimum clear opening of 30 inches to permit wheelchair and mobility aid users to be evacuated to an adjoining vehicle in an emergency...
-
11B-703.7.2.4 Assistive listening systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 11B-703.7.2.4....
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the finish...
-
Visual Alarms
Visual Alarms • Where audible fire alarms or emergency notification is provided, flashing lights are required in public and common use areas, including toilet and bath rooms, locker rooms...
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the floor...
-
Speech Disabilities
The only “standard” building egress systems that may require a person to have the ability to speak in order to evacuate a building are the emergency phone systems in areas of refuge, elevators...
- AquaTrek2 ADA Transfer System