Protruding objects shall comply with Section 11B-307.
Search Results "Ceiling Mounted Patient Lift"
Commonly Searched Documents
-
11B-307.1 General
-
11B-307.1 General
Protruding objects shall comply with Section 11B-307.
-
11B-307 Protruding objects
[See subsections ...]
-
11B-204 Protruding objects
[See subsections ...]
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and...
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and...
-
M301.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and shall comply with M305.4.
- Nondiscrimination in Health Programs and Activities
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
The transfer surface dimensions do not include headrests, footrests, or similar supports for body extremities that do not support the patient’s overall body position....
-
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests
The current design allows only one long side for transfer, which limits some patient transfers where a patient can use only one side of the body due to paralysis on one side or other such...
-
M303.2.1 Orientation
Wheelchair spaces shall be designed so that a patient seated in a wheelchair orients in the same direction that a patient not seated in a wheelchair orients when the diagnostic equipment...
-
M303.2.1 Orientation
Wheelchair spaces shall be designed so that a patient seated in a wheelchair orients in the same direction that a patient not seated in a wheelchair orients when the diagnostic equipment...
-
§ 38.23(b)(5) Platform barriers
The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the platform during its operation....
-
Width of Spaces [1012.2]
Parking spaces and pull-up spaces for RVs must be at least 20 feet wide to accommodate RVs equipped with a lift (figure 27)....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
5.1.3 Transfer Surface Low Height Options for M301 and M302 The Committee did not agree on a final low height recommendation. Rationale for final recommendation (more detail...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments.
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum.
-
410.4 Platform to Runway Clearance
The clearance between the platform sill and the edge of any runway landing shall be 1 inch (32 mm) maximum.
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
410.4 Platform to Runway Clearance