Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
Search Results "Boarding Platform"
-
1132A.4, Item 3
-
410.6 Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum....
-
5.8.2.1 Height of Breast Platform At Time of Measurement
5.8.2.1 Height of Breast Platform At Time of Measurement. All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations Description: The knee and toe clearance under the breast platform applies to mammography equipment for...
-
1017.1 General
Federal agencies must document the basis for their determination when using Exceptions 1 or 2, and must notify the Access Board when using Exception 2. See F201.4.1....
-
1017.1 General
Federal agencies must document the basis for their determination when using Exceptions 1 or 2, and must notify the Access Board when using Exception 2. See F201.4.1....
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides....
-
Requirements to Remember for ADA Compliance in Construction Projects: Transportation Facilities
Both the DOT and DOJ standards are based on the United States Access Board ADA Accessibility Guidelines (ADAAG)....
- Access Board: Parallel Approach at an Alcove
- Access Board: Forward Approach at an Alcove
- Access Board: Clear Width at Turn
-
7.3 Definitions
are from the Forest Service Manual or Handbook, the Forest Service Infra Trails Module, Trail Assessment and Condition Survey (TRACS) reference materials, or are mandated by the Access Board...
-
Seat Heights
Seat Heights: Transfer platforms in play areas need to be between 11 and 18 inches maximum above the ground (ADA-ABA Section 1008.3.1.2)[7]....
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height....
-
Transfer Supports
Transfer supports must be provided on transfer platforms and transfer steps at each level where transferring is the intended method of access. ...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less in height...
-
§ 38.113(d)(3) Exception
Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d) (1) or (2), platform or portable lifts complying with §38.125(b) of this part, or...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a transition...
- United States Access Board
-
Americans with Disabilities Act (ADA) Standards for Transportation Facilities
These standards are closely based on the Board's ADA Accessibility Guidelines (ADAAG) but include additional requirements concerning: Location of Accessible Routes (206.3)...
-
M303.2.2 Width (Section-by-Section Analysis)
However, the Board added a new exception for wheelchair spaces on raised platforms, as discussed in Section IV.C.1....