supports to be moved out of the way after transfer....
Search Results "Transfer Wall"
-
M305.2.8 Fittings (Section-by-Section Analysis)
-
Examples of access:
Transfer help or equipment You might need help to get on to an exam table. If staff can’t move you, look for an office with equipment....
-
VOLUNTARY COMPLIANCE AGREEMENT
BETWEEN
THE UNITED STATES OF AMERICA
AND
THOMAS JEFFERSON UNIVERSITY HOSPITALS INC.
&
OUTPATIENT IMAGING AFFILIATES, LLC.
DJ# 202-62-458
VOLUNTARY COMPLIANCE AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND THOMAS JEFFERSON UNIVERSITY HOSPITALS INC. & OUTPATIENT IMAGING AFFILIATES, LLC. DJ# 202-62-458
-
604.5.1 Side Wall
604.5.1 Side Wall....
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer....
-
Plan 6B: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, wardrobe, and door connecting to adjacent guest room....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
-
M305.2.2 Length (Section-by-Section Analysis)
table at the designated transfer location for at least the minimum width of the transfer surface, with a minimum length of 28 inches....
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, open clothes closet, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support....
-
M305.2.2 Length
The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2....
-
Plan 6A: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest...
- Bobrick 18" Straight Grab Bar Peened B-6806.99 x 18
- Bobrick 18" Straight Grab Bar B-6806 x 18
- Bobrick 18" Straight Grab Bar B-5806 x 18
- Bobrick 18" Straight Grab Bar Peened B-5806.99 x 18
-
Plan 5A: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest room....
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
- Just Manufacturing 24" Stainless Steel Grab Bar
- Just Manufacturing 36" Stainless Steel Grab Bar
-
604.5.2 Rear Wall
604.5.2 Rear Wall....
-
711.3.3 Ducts and air transfer openings
Penetrations of fire-resistance-rated walls by ducts and air transfer openings that are not protected with fire dampers shall comply with this section....